[ CVE-2026-63351 · Published 13 Oct 2026 ]

Vulnerability in Siemens SIMATIC Drive Controller CPU 1504D TF

CVSS 6.1 EPSS <1%3 agency advisoriesNo fix listed yet

[ Description ]Official description

Affected devices do not properly validate and sanitize visual properties of calculated signals contained in imported CSV trace files before rendering them on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Successful exploitation could allow attacker-controlled JavaScript to execute in the user’s browser session and perform PLC operations through the web server within the scope of the user’s authorization.

[ Fixes ]Fixes and patches

No fix or interim patch is linked from our sources yet. Check the vendor references below and limit exposure of affected systems until a fix is available.

[ Advisories ]Government CERT advisories

  • NCSC-NLNCSC-2026-0415

    Vulnerabilities fixed in Siemens products Translated from Dutch

    Probability/damage M/HCVE-2024-7322CVE-2025-6965CVE-2025-70873+38 more CVEs
  • CERT-FRCERTFR-2026-AVI-1298

    Multiple vulnerabilities in Siemens products Translated from French

    Multiple vulnerabilities have been discovered in Siemens products. Some of them allow an attacker to cause remote arbitrary code execution, privilege escalation and remote denial of service.

    CVE-2021-41617CVE-2023-28531CVE-2023-51384+716 more CVEs
  • BSI CERT-BundWID-SEC-2026-3891

    Siemens SIMATIC S7: Multiple vulnerabilities Translated from German

    CVE-2026-46331CVE-2024-49998CVE-2025-21779+384 more CVEs