[ CVE-2026-58115 · Published 11 Aug 2026 ]

Vulnerability in Siemens SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2)

CVSS 10.0 EPSS <1%2 agency advisories Fix available

[ Why it matters ]Priority signals

  • Critical severity: CVSS 10.0

[ Description ]Official description

A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions running Example Image versions with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server. This could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges.

[ Fixes ]How to fix it

Fixed versions

  • Siemens SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2): upgrade to V4.3.4-1 or laterEarlier versions are listed as affected
  • Siemens SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2): upgrade to V4.3.4-1 or laterEarlier versions are listed as affected
  • Siemens SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2): upgrade to V4.3.4-1 or laterEarlier versions are listed as affected
  • Siemens SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2): upgrade to V4.3.4-1 or laterEarlier versions are listed as affected

From the affected-version ranges in the CVE record. Check the vendor's advisory for the exact release for your platform or branch.

Until you can patch: our advice

  1. Put the login behind a VPN or allow-list. This flaw gets around authentication or access checks. Make the login and admin pages reachable only from trusted networks or through a VPN, and look for accounts, sessions and settings you don't recognise.
  2. Keep it off the internet. It can be attacked over the network without an account. Until you have patched, make sure the affected service is not reachable from the internet: close the port, or put it behind a VPN or a firewall allow-list.

[ Advisories ]Government CERT advisories