[ CVE-2026-4638 · Published 24 Sep 2026 ]

Vulnerability in Paessler GmbH PRTG Network Monitor

CVSS 7.1 EPSS <1%1 agency advisoryNo fix listed yet

[ Description ]Official description

PRTG Network Monitor before version 26.2.120.1449 ships a demo EXE/Script sensor that multiplies two integer parameters using cscript.exe. If a non-numeric value is passed instead, cscript.exe raises a 'Type mismatch' runtime error that includes the offending parameter value in plaintext. PRTG provides a documented placeholder variable, %windowspassword, which resolves to the configured Windows/domain password used by PRTG and can be passed as a sensor parameter.  Any PRTG user who is not restricted to read-only access and is permitted to create sensors (the default for non-read-only users) can pass %windowspassword as an argument to the demo VBScript sensor, triggering the type-mismatch error and causing PRTG to display the plaintext password in the sensor's error output.

[ Fixes ]Fixes and patches

No fix or interim patch is linked from our sources yet. Check the vendor references below and limit exposure of affected systems until a fix is available.

[ Advisories ]Government CERT advisories